Airflow Systems: Difference between revisions

m
no edit summary
mNo edit summary
mNo edit summary
Line 35: Line 35:
*The manual shows a 90 degree fitting for the dryer with service port however the kit contains a 90 degree fitting without a port and a straight hose coupling with port. None of the drawings or pictures show this new variation. See also this [https://www.facebook.com/groups/249625742733962/posts/692509681778897 FB thread]. The kit now assumes, you mount the new inline service port at the front edge of the shelf wherever convenient.
*The manual shows a 90 degree fitting for the dryer with service port however the kit contains a 90 degree fitting without a port and a straight hose coupling with port. None of the drawings or pictures show this new variation. See also this [https://www.facebook.com/groups/249625742733962/posts/692509681778897 FB thread]. The kit now assumes, you mount the new inline service port at the front edge of the shelf wherever convenient.
* In order to mark the two holes for the condenser fittings one needs to make a template. A good way is to first make very large holes roughly where they need to be, then pass the fittings through those holes (make sure they are perpendicular to the condenser), then take additional snippets that have half-hole cutouts at their edges and tape them to the template so the half-holes touch the fitting.
* In order to mark the two holes for the condenser fittings one needs to make a template. A good way is to first make very large holes roughly where they need to be, then pass the fittings through those holes (make sure they are perpendicular to the condenser), then take additional snippets that have half-hole cutouts at their edges and tape them to the template so the half-holes touch the fitting.
*The manual doesn't state where left and right is on the master hose plan. Since the VS/rudder isn't drawn, one might think that the plan is as seen from the bottom, however, the plan is drawn looking down on the plane.
*When running the hoses outside the tunnel, they recommend running them to the right side of the firewall as the left side is busy with the oil cooler.
*The manual says nothing about doublers for the condenser holes, but the kit includes doublers. The holes in the doublers are a bit too small, the 90 degree fittings won't pass through. The doublers can be riveted to the inside of the bottom skin using 4 AN470 4-4 rivets.<br>[[File:2022-10-29 18-38-22.jpg|400x400px]]
*The manual says nothing about doublers for the condenser holes, but the kit includes doublers. The holes in the doublers are a bit too small, the 90 degree fittings won't pass through. The doublers can be riveted to the inside of the bottom skin using 4 AN470 4-4 rivets.<br>[[File:2022-10-29 18-38-22.jpg|400x400px]]
3,777

edits

MediaWiki spam blocked by CleanTalk.