Black Max Hints: Difference between revisions

m
no edit summary
mNo edit summary
mNo edit summary
Line 1: Line 1:
* The unit does not validate proper operation, best to add an inline hygrometer as described in section [[Engine_Dehydration#Accessories]]
* The unit does not validate proper operation, best to add an inline hygrometer as described in section [[Engine_Dehydration#Accessories]].
*The Peltier element may become weak which leads to improper dehydration. To validate proper cooling, open the device (caution: 120V inside, also on the PCB) and measure the voltage of the temperature sensor between the black and white wires<br>[[File:Screen Shot 2023-07-08 at 12.18.30 AM.png|400x400px]]<br>The voltage must be lower than 0.6 volts in the cooling cycle.
*The Peltier element may become weak which leads to improper dehydration. To validate proper cooling, open the device (caution: 120V inside, also on the PCB) and measure the voltage of the temperature sensor between the black (BL) and white (WH) wires<br>[[File:Screen Shot 2023-07-08 at 12.18.30 AM.png|400x400px]]<br>The voltage must be lower than 0.6 volts in the cooling cycle.
3,763

edits

MediaWiki spam blocked by CleanTalk.